SAFETY SWITCHES
> Right Angle Rope Operated
|
| Previous Page | Next Page | View Printer-Friendly Page |
| Safety Switches Right Angle Rope Pull - Metal Housing |
![]() |
|
| Advance Controls’
Right Angle Rope Operated Safety Switches are designed to protect
large (up to 114.8 feet - 35 meters with intermediate supports)
open operating areas. The activating rope must be tensioned.
Tensioning the activating rope transfers the Normally Closed
contact into the "closed" position. Cutting or pulling the rope past the operating point, mechanically forces open the normally closed safety contact turning “Off” the machine's control power. The machine cannot be restarted until the rope is properly tensioned and the normally closed safety contact "closed". The switch has a green collar to indicate when the rope is properly tensioned. |
| Indicating Type Manual Reset
Automatic Reset
|
![]() |
|||||||||||||||||||||
|
Technical
Specifications - Contact Rating
|
Positive forced break double contacts. Maximum contact operating Voltage: 600 VAC, 300 VDC (UL508) Short circuit protection: 10 Amps (max) fuse Electrically isolated contacts allow different contact voltages. |
||||||||||||||||