General
Specifications
Enclosure: Die cast metal with baked epoxy powder
coating.
Compliance: Low Voltage Directive 773/23/CEE:
Directive 93/68/CEE: Machinery Directive 89/392/CEE
Conduit Entry: One Entry = PG13.5 (PG13.5 to ½"
NPT conduit adapter furnished standard)
Mechanical Endurance:
Life Cycle: 1 Million Operations
Operating Temperature Range: -13° to +175° F (-25° to
+80° C)
Activating Speed Minimum: 0.039 inches / sec (1 mm/sec)
Standards:
UL 508,
CSA C22-2nr.14, CEI EN 60947-5-1, EN 292, EN 418, EN 1088,
EN 60204, EN 60947-5-1, IEC 204, IEC 337-1, IEC 947-5-1,
NFC 63-140, VDE0113, VDE 0660, BG-GS-ET-15
Positive Break Contacts are in compliance with
standards: CEI EN60947-5-1, EN 60947-5-1, IEC 947-5-1,
VDE0660-206
Protection Class: IP66 (according to IEC529)
Operating Force:
Initial = 14 lbs. (64 N)
Final = 19 lbs. (83 N)
Recommended Maximum Operating Distance:
Without intermediate supports = 19.5 feet (6 meters)
With intermediate support = 39.4 feet (12 meters)
Intermediate support = every 9.8 feet (3 meters)
|
 |
|
Installation
- Connect Safety Circuit
to the Normally Closed contact (21-22). The Normally Open
contact is for indicators, etc. When the activating rope
is properly tensioned the Normally Closed contacts are
"closed". If the rope is cut or pulled, the Normally Closed
contact opens, turning "off" the machine control power.
- Mount the switch
using tamper-resistant fasteners (not supplied). Always
use washers under the switch mounting fasteners to prevent
the fasteners from pulling through the switch mounting
holes.
- Rope tensioning
- see Figure 1.
The rope is properly tensioned when the end of the indicator
covers about half of the green collar. Once the activating
rod is positioned, the "automatic reset" types will automatically
transfer the contacts into the "closed" position. To transfer
the contacts in the "manually reset" types, pull out the
"reset" knob.
- The contacts transfer
if the activating rope is either cut or pulled. To reset
the switch reset the rope tension as described in Item
3 above.
- Do not use the switch
as a mechanical stop.
- Verify proper operation
of the Safety Switch before placing the machine in service.
|
 |
 |
Safety Switch Applications
Typical application for the Top Entrance Rope Operated
Safety Switch. |